CMP - Two-Element Air-Spaced Condensers
 
Related Products
 
 
 
   •    Condensers for projection systems
   •    Designed for efficient radiant energy transfer and uniform film-gate illumination
   •    Optimized air-spaced condensers are intended for close and efficient source coupling - Conjugate ratios from 3.0 to 15.0 with peak performance at 5.0
   •    Symmetric air-spaced condensers are intended for use at or close to unit magnification - Conjugate ratios from 0.3 up to 3.0, with peak performance at 1.0
   •    The low-expansion borosilicate glass condensers are suitable for normal applications and offer high transmission
   •    Synthetic fused-silica condensers combine superb transmission, especially in the ultraviolet, with extreme resistance to high temperature and thermal shock
 
We want your Feedback
See what's in stock NOW
OverviewSpecsFAQsCustomizeDownloadsCool-Tips
Condensers are used to project or display an image of an illuminated object. Examples include film and slide projectors, integrated circuit mask projectors, optical comparators, profile gauges, and similar equipment. A condenser has two primary duties in projection systems. It must first transfer radiant energy efficiently from a light source to the entrance pupil of a projection lens system, so that the brightness of the projected image is maximized. Second, it must provide highly uniform illumination of the object plane or film gate (the location of a slide, motion picture, or microfilm frame) to be projected.

CVI Melles Griot two-element air-spaced condensers are designed to do both of these tasks efficiently over a large range of conjugate ratios and at a low f-number. They are available in two materials and are well suited for applications requiring efficiency and uniformity.
Efficient radiant energy transfer from a source into the projection lens system is accomplished by using a condenser close to the source, with minimum spherical aberration at the resultant large conjugate ratio. Low f-number operation is also obviously advantageous. Spherical aberration, which at low f-numbers can cause significant energy loss, has been minimized in CVI Melles Griot condensers by a two-element air-spaced design. The f-number for all condensers is 1.0.
Uniform film-gate illumination is achieved by placing the gate close to the condenser's secondary principal plane. Irradiance distributions at the condenser principal planes are essentially identical. If an ideal point source is used, irradiance distribution at the condenser's primary principal plane would be nonuniform by inverse square law approximation. The finite size of real sources considerably improves uniformity of distribution at the primary principal plane of the condenser. Clearly there is a trade-off between uniform film-gate illumination and the proximity of the condenser to the source (large conjugate ratio). CVI Melles Griot condensers have been designed to be short, allowing close approach to condenser principal planes. If necessary, a flat hot mirror and/or heat-absorbing glass filter can be placed between the condenser and the film gate. Film, filter (if any), and condenser can all be forced-air cooled. The condenser housing has six vent holes to enhance cooling. Lenses can be easily removed from the housing for cleaning.


CMP two-element symmetric air-spaced condensers


CMP two-element optimized air-spaced condensers

 
 
  See what's in stock NOW
Part NumberFormer MG Part Numberf
(mm)
φ
(mm)
L
(mm)
CA
(mm)
A1H
(mm)
A4H"
(mm)
E1H
(mm)
E2H"
(mm)
Optical MaterialTypePriceAdd
to
Cart
In
Stock
CMP-10.0-16.0-3.7601 CMP 10110.016.014.2710.03.76-1.028.0-4.6LEBGOptimized$180Add to CartYes
CMP-15.0-22.0-5.3601 CMP 10715.022.019.0515.05.36-2.3410.1-6.1OQSFSOptimized$580Add to CartEmail
CMP-25.0-33.0-6.5001 CMP 10925.033.022.2325.06.50-2.5712.0-5.1LEBGOptimized$831Add to CartEmail
CMP-50.0-58.0-11.4801 CMP 11750.058.030.1550.011.48-4.6716.4-5.2LEBGOptimized$279Add to CartEmail
CMP-75.0-85.0-13.9201 CMP 12175.085.034.9875.013.92-6.3820.2-5.1LEBGOptimized$301Add to CartEmail
CMP-75.0-85.0-14.9401 CMP 12375.085.034.9875.014.94-6.6020.9-3.6OQSFSOptimized$1,581Add to CartEmail
CMP-10.0-16.0-2.4201 CMP 00110.016.014.2710.02.42-2.426.1-6.1LEBGSymmetric$261Add to CartEmail
CMP-15.0-22.0-2.8701 CMP 00515.022.015.8815.02.87-2.876.7-6.7LEBGSymmetric$128Add to CartEmail
CMP-25.0-33.0-3.8101 CMP 00925.033.019.0525.03.81-3.817.9-7.9LEBGSymmetric$229Add to CartEmail
CMP-75.0-85.0-8.9301 CMP 02175.085.034.9875.08.93-8.9313.6-13.6LEBGSymmetric$281Add to CartEmail
HyperLink HyperLink HyperLink HyperLink
     > About CVI MG
     > Catalog Request
     > Credit Application
     > Employment
     > Feedback
     > International Reps
     > Locations
     > News
     > Phone Numbers
     > Privacy Statement
     > Terms and Conditions
     > Trade Shows
     > Optical Components
     > Lasers
     > Optical Assemblies
     > Apertures & Spatial Filters
     > Electronic Shutters
     > Opto-Mechanical Assemblies
     > Tables & Breadboards
     > Instruments
     > Lab Accessories
     > Contact Us
     > My Account
     > Shipping Policy
     > Create an Account
Facebook
Twitter

McAfee Secure sites help keep you safe from identity theft, credit card fraud, spyware, spam, viruses and online scams
Home |  Catalog Request |  My Account |  Contact Us |  About Us |  Employment |  Locations |  Sales: 505-296-9541
Copyright © 2000-2011 by CVI Melles Griot and Auburn SeeWolf, LLC